Skip to content
Register

Panels & modular · Recessed, low glare

ADAAR I-LIGHT

Range code ADAAR I-LIGHT

ADAAR I-LIGHT draws the eye with lines, not glare: the ADAAR recessed module with one to four slim lens lines, reflector and lens optics keeping UGR as low as 16. 595 x 595 or 295 x 1195mm for exposed T or plasterboard ceilings, up to 4,982 lm at 160 lm/W, fixed output, DALI or Casambi, integral emergency. Toe the line.

Up to4,982lm (595 x 595 4L, 33 W, 4000 K)
160lm/W Up to, 4000 K
UGR<16 As low as
1-4 Lens lines
595 x 595 or 295 x 1195mm; 60mm deep IP20 840 · 830 White textured matt RAL 9003

Technical information

Enter the bold lumen value in Relux.

Higher emergency output (6 W) on request.

Light distribution

cd/klm
2004006008001000
C0–C180 C90–C270

Intensities in cd/klm, so the shape applies to every output.

Part-code builder

Pick one option in each position. Every combination shown is a valid build.

1 Range
ADAAR I-LIGHT
2 Size
595 x 595mm
3 Lens lines
Three lens lines 1L: Only with 295 x 1195mm
4 Output (W)
18 W Depends on: Size, Lens lines
5 Colour temperature
4000 K, CRI >80
6 Finish
White RAL 9003 textured matt
7 Control gear
Fixed output
8 Ceiling
Exposed T
9 Emergency
No emergency
Your part code The wattage follows the size and number of lens lines.
Add to schedule

Also in the range

Installation images

ADAAR I-LIGHT installed, picture 1
Free lighting design service Not sure which output? Send us the drawings. We lay out the scheme with ADAAR I-LIGHT, calculate it in Relux to EN 12464-1 and return marked-up plans with part codes.
Request a lighting design

Features

  1. 01Recessed modular luminaire with one to four lens lines
  2. 02Reflector and lens optics: UGR as low as <16
  3. 03595 x 595 (2, 3 or 4 lines) or 295 x 1195mm (1 or 2 lines)
  4. 04Up to 4,982 lm and 160 lm/W; 4000 K or 3000 K, CRI >80, 3 SDCM
  5. 05Fixed output, DALI or Casambi wireless (bDW), integral Tridonic gear
  6. 06Exposed T or plasterboard ceilings; tool-free mounting brackets
  7. 07Powder-coated steel housing, white RAL 9003 textured matt
  8. 08Integral emergency EM, EMST or EMD2; L80B10 >102,000 h

Specification

IP
IP20
IK
IK05
UGR
As low as <16
Lifetime
102,000 h
Colour options
840, 830
Controls
FI, DALI, bDW
Emergency
EM, EMST, EMD2 (integral)
Mounting
Recessed: exposed T or plasterboard (cut-out)
Finish
WHITE White textured matt (RAL 9003)
Supply
230 V 50 Hz
Electrical class
Class I
Dimensions
595 x 595 or 295 x 1195mm; 60mm deep
Warranty
5 years

Control gear, standards & warranty

  • UKCA
  • CE
  • RoHS
  • WEEE
  • 230 V 50 Hz
  • Class I
  • IP20
  • Emergency BS 5266-1

Tridonic control gear as standard, integral to the luminaire: fixed output, DALI or Casambi wireless (bDW). Integral emergency: 3hr manual test, self-test or DALI-2.

diVa five year warranty

Downloads

Need photometric files, installation instructions or a BIM object not listed here? Ask our technical team.