Skip to content
Register

Industrial & high bay · IP65 batten

HERCULES LED

Range code HELED

HERCULES LED is a sealed IP65 batten built for the places lighting has to work hardest: data centres, plant rooms, cold stores and food preparation areas. A high-impact polycarbonate body and opal diffuser keep the CREE boards clean and spot-free, and stainless steel clips come as standard where others make do with plastic. Single or twin, 600 to 1500mm and 2,000 to 13,000 lm, with DALI, corridor function and integral emergency for long data hall aisles. A labour of Hercules, made light work.

212lm/W Peak efficacy, board lumens
IP65 IK10 polycarbonate, stainless clips
Up to13,000lm Output (twin 1500) · outputs from 2,000 lm
125kh L80B10, LED boards
Lengths 618 / 1215 / 1515mm (618 twin only); width 81mm single, 116mm twin; 75mm deep; fixing centres 411 / 800 / 1000mm IP65 830 · 835 · 840 · 850 · 860 · 865 (80 CRI); 940 (90 CRI). Photometrics at 840

Technical information

Enter the bold lumen value in Relux.

High output emergency (6 W): EMHO, EMSTHO or EMD2HO.

Single 1200
Output lmWlm/WEmergency lm (2 W)Emergency lm, HO (6 W)Photometric file
20009.6208.34401,315 HELED-1-2000-840-1200.LDT
270012.9209.34401,320 HELED-1-2700-840-1200.LDT
330016.3202.54251,275 HELED-1-3300-840-1200.LDT
395019.8199.54201,255 HELED-1-3950-840-1200.LDT
460023.3197.44151,245 HELED-1-4600-840-1200.LDT
520026.9193.34051,220 HELED-1-5200-840-1200.LDT
Single 1500
Output lmWlm/WEmergency lm (2 W)Emergency lm, HO (6 W)Photometric file
250012.0208.34401,315 HELED-1-2500-840-1500.LDT
330016.2203.74301,285 HELED-1-3300-840-1500.LDT
417520.4204.74301,290 HELED-1-4175-840-1500.LDT
495024.8199.64201,255 HELED-1-4950-840-1500.LDT
576029.2197.34151,245 HELED-1-5760-840-1500.LDT
650033.7192.94051,215 HELED-1-6500-840-1500.LDT

Light distribution

cd/klm
50100150200250
C0–C180 C90–C270

Intensities in cd/klm, so the shape applies to every output.

Part-code builder

Pick one option in each position. Every combination shown is a valid build.

1 Range
HERCULES LED
2 Housing
Twin housing
6 Length
1515mm
3 Output (lm)
8,350 lm Depends on: Housing, Length
4 CRI / CCT
80 CRI, 4000 K
5 Control gear
Fixed output
7 Clips
Stainless steel clips
8 Sensor
No sensor MSD2: Requires DALI driver; only with twin housing and 1200 or 1500 (length) · PIR-DD, PIR-D2: Requires DALI driver
9 Emergency
No emergency Depends on: Control gear
Your part code Outputs are board lumens. MS and MSD2 on twin 1200 and 1500 only; MSD2 needs DALI gear.
Add to schedule

In use

Free lighting design service Not sure which output? Send us the drawings. We lay out the scheme with HERCULES LED, calculate it in Relux to EN 12464-1 and return marked-up plans with part codes.
Request a lighting design

Features

  1. 01Surface or suspended installation, single or twin housing
  2. 02High-impact polycarbonate housing and opal diffuser, IK10
  3. 03IP65, with stainless steel clips as standard
  4. 04CREE LED boards, 2,000 to 13,000 lm, up to 212 lm/W
  5. 05Lengths 1200 and 1500mm; 600mm in twin housing
  6. 06Tridonic gear: fixed output, DALI, corridor function, 1-10V or Casambi wireless
  7. 07Integral emergency: 3hr manual test, self-test or DALI-2 (EMD2). Microwave sensors (MS, MSD2) on 1200 and 1500mm twins; batten mount PIR on all sizes
  8. 08L80B10 > 125,000 h (LED boards, 250 mA, Tc 85 °C)

Specification

IP
IP65
IK
IK10
Lifetime
125,000 h
Colour options
830, 835, 840, 850, 860, 865 (80 CRI); 940 (90 CRI). Photometrics at 840
Controls
FI, DALI, swDIM, CF10, 1-10V, bDW
Emergency
EM, EMST, EMD2 (integral); high output EMHO, EMSTHO, EMD2HO (6 W)
Mounting
Surface or suspended; stainless steel clips (SS)
Supply
230 V 50 Hz
Electrical class
Class I
Dimensions
Lengths 618 / 1215 / 1515mm (618 twin only); width 81mm single, 116mm twin; 75mm deep; fixing centres 411 / 800 / 1000mm
Warranty
5 years

Emergency battery

HERCULES LED emergency versions run on high-temperature lithium iron phosphate (LiFePO4) batteries, selected and tested for self-contained emergency lighting, so they stay dependable in warm spaces such as data centres and plant rooms.

Ambient temperature
0 to 60 °C continuous operation (charging 0 to 60 °C, 0 to 45 °C recommended)
Chemistry
Lithium iron phosphate (LiFePO4), high-temperature cells, 3.2 V
2 W emergency
2-cell pack, 3.0 Ah (9.6 Wh): single 1200 / 1500 and twin 600
3 W emergency
3-cell pack, 4.5 Ah (14.4 Wh): twin 1200 / 1500
6 W emergency (HO)
Two 3-cell packs, 2 x 4.5 Ah (2 x 14.4 Wh)
Duration
3 hours (BS 5266-1)
Recharge
24 hours
Standby
Very low self-discharge, so standby power is considerably reduced
Life
At least 2,000 cycles or 4 years (reference) to 75% capacity at 0 to 50 °C ambient
Certification
IEC 62133, IEC 62620, UN38.3 and UN3481 (transport); 3-cell packs ICEL endorsed; BSI verified
diVa LiFePO4 battery

Control gear, standards & warranty

  • UKCA
  • CE
  • RoHS
  • WEEE
  • 230 V 50 Hz
  • Class I
  • Flicker free (IEEE 1789)
  • Emergency BS 5266-1

Tridonic control gear as standard. Helvar, Philips, Inventronics and unbranded options available upon request. Fixed output, DALI, corridor function (10% background as standard, other levels programmed to order), 1-10V and Casambi wireless gear available.

diVa five year warranty

Downloads

Need photometric files, installation instructions or a BIM object not listed here? Ask our technical team.