SCYTHES is a compact adjustable downlight with a die-cast, 2mm low-profile bezel, round or square, in white RAL 9003. A 36 degree faceted reflector puts 775 lm exactly where it is aimed from a 70mm cut-out, IP44 from below and flicker free. Dimming, Casambi and emergency options. Small cut, sharp edge.
Technical information
Enter the bold lumen value in Relux.
Higher emergency outputs (3 W and 6 W) on request.
| Output lm | W | lm/W | Emergency lm (2 W) | Photometric file |
|---|---|---|---|---|
| 750 | 8.00 | 93.8 | 195 | SC-775-830.LDT |
| 775 | 8.00 | 96.9 | 205 | SC-775-840.LDT |
Light distribution
cd/klmIntensities in cd/klm, so the shape applies to every output.
Part-code builder
Pick one option in each position. Every combination shown is a valid build.
Features
- 01Compact adjustable downlight; 70mm cut-out, 74mm deep
- 02Die-cast 2mm low-profile bezel, round Ø80 or square 80 x 80mm
- 03White RAL 9003 as standard; any RAL to order
- 04Injection-moulded 36° faceted reflector, low glare
- 05775 lm at 8 W (840); 4000 K or 3000 K, CRI >80, 3 SDCM
- 06No visible flicker (IEEE 1789); IP44 front, IP20 rear
- 07Fixed output, DALI, mains dimming or Casambi wireless
- 08Emergency EM, EMST or EMD2; L70/F50 >50,000 h
Specification
- IP
- IP44 front, IP20 rear
- Lifetime
- 50,000 h
- Colour options
- 840, 830
- Controls
- FI, DALI (also switchDIM, DSI), MDIM, bDW
- Emergency
- EM, EMST, EMD2
- Mounting
- Recessed, 70mm cut-out
- Finish
- WH White (9003)
- Supply
- 230 V 50 Hz
- Electrical class
- Class II
- Dimensions
- 70mm cut-out; round Ø80mm or square 80 x 80mm bezel; 74mm recess; 0.3 kg
- Warranty
- 5 years
Control gear, standards & warranty
- UKCA
- CE
- RoHS
- WEEE
- 230 V 50 Hz
- Class II
- IP44
- Emergency BS 5266-1
Fixed output, DALI (also switchDIM and DSI), mains dimming or Casambi wireless (bDW). Emergency EM, EMST or EMD2.