Skip to content
Register

Panels & modular · Clip-in panel

TYRO PRO: CLIP-IN (SAS150)

Range code TYPRO

TYRO PRO: CLIP-IN is a project luminaire made for premium clip-in metal ceilings such as SAS120 / SAS150, Armstrong Clip-F and Burgess A-Bar, where standard panels will not fit. Flush with the tiles and fitted without tools; edge-lit or back-lit to suit the ceiling, in 10 standard tile sizes or made to measure, each at three outputs and 120 or 170 lm/W. Made to project order: MOQs apply, lead time approximately 12–16 weeks.

170lm/W Up to; high efficacy versions
UGR<19 Micro-prismatic diffuser
30mm Panel depth, from
Up to8,500lm
Tile size less 1mm, from 30mm deep (edge-lit or back-lit to suit the ceiling): 300x300, 300x600, 300x900, 300x1200, 300x1500, 300x1800, 500x500, 600x600, 600x1200, 750x750mm; bespoke sizes to order IP20 830 · 835 · 840 · 860 · 940 White RAL9010
Made to project orderTYRO PRO is a project luminaire, manufactured for each project to suit the ceiling system. Minimum order quantities apply and the lead time is approximately 12–16 weeks from order. Please discuss your ceiling system and programme with the diVa sales office at the design stage.

Technical information

Enter the bold lumen value in Relux.

Higher emergency outputs (3 W and 6 W) on request.

330 · 300 x 300mm
Output lmWlm/WEmergency lm (2 W)Photometric file
7507.5100.0210 TYPRO-750-840-330-UGR.LDT
113011.3100.0210 TYPRO-1130-840-330-UGR.LDT
12807.5170.7360 TYPRO-1280-840-330-UGR.LDT
150015.0100.0210 TYPRO-1500-840-330-UGR.LDT
191011.3169.0355 TYPRO-1910-840-330-UGR.LDT
255015.0170.0355 TYPRO-2550-840-330-UGR.LDT
550 · 500 x 500mm
Output lmWlm/WEmergency lm (2 W)Photometric file
180015.0120.0250 TYPRO-1800-840-550-UGR.LDT
255015.0170.0355 TYPRO-2550-840-550-UGR.LDT
270022.5120.0250 TYPRO-2700-840-550-UGR.LDT
3600 STD30.0120.0250 TYPRO-3600-840-550-UGR.LDT
383022.5170.2355 TYPRO-3830-840-550-UGR.LDT
510030.0170.0355 TYPRO-5100-840-550-UGR.LDT
630 · 300 x 600mm
Output lmWlm/WEmergency lm (2 W)Photometric file
120010.0120.0250 TYPRO-1200-840-630-UGR.LDT
170010.0170.0355 TYPRO-1700-840-630-UGR.LDT
180015.0120.0250 TYPRO-1800-840-630-UGR.LDT
240020.0120.0250 TYPRO-2400-840-630-UGR.LDT
255015.0170.0355 TYPRO-2550-840-630-UGR.LDT
340020.0170.0355 TYPRO-3400-840-630-UGR.LDT
660 · 600 x 600mm
Output lmWlm/WEmergency lm (2 W)Photometric file
180015.0120.0250 TYPRO-1800-840-660-UGR.LDT
255015.0170.0355 TYPRO-2550-840-660-UGR.LDT
270022.5120.0250 TYPRO-2700-840-660-UGR.LDT
3600 STD30.0120.0250 TYPRO-3600-840-660-UGR.LDT
383022.5170.2355 TYPRO-3830-840-660-UGR.LDT
510030.0170.0355 TYPRO-5100-840-660-UGR.LDT
930 · 300 x 900mm
Output lmWlm/WEmergency lm (2 W)Photometric file
150012.5120.0250 TYPRO-1500-840-930-UGR.LDT
213012.5170.4360 TYPRO-2130-840-930-UGR.LDT
225018.8119.7250 TYPRO-2250-840-930-UGR.LDT
300025.0120.0250 TYPRO-3000-840-930-UGR.LDT
319018.8169.7355 TYPRO-3190-840-930-UGR.LDT
425025.0170.0355 TYPRO-4250-840-930-UGR.LDT
1230 · 300 x 1200mm
Output lmWlm/WEmergency lm (2 W)Photometric file
180015.0120.0250
255015.0170.0355
270022.5120.0250
3600 STD30.0120.0250
383022.5170.2355
510030.0170.0355
1260 · 600 x 1200mm
Output lmWlm/WEmergency lm (2 W)Photometric file
300025.0120.0250
425025.0170.0355
450037.5120.0250
600050.0120.0250
638037.5170.1355
850050.0170.0355
1530 · 300 x 1500mm
Output lmWlm/WEmergency lm (2 W)Photometric file
210017.5120.0250 TYPRO-2100-840-1530-UGR.LDT
298017.5170.3360 TYPRO-2980-840-1530-UGR.LDT
315026.3119.8250 TYPRO-3150-840-1530-UGR.LDT
420035.0120.0250 TYPRO-4200-840-1530-UGR.LDT
446026.3169.6355 TYPRO-4460-840-1530-UGR.LDT
595035.0170.0355 TYPRO-5950-840-1530-UGR.LDT
1830 · 300 x 1800mm
Output lmWlm/WEmergency lm (2 W)Photometric file
270022.5120.0250 TYPRO-2700-840-1830-UGR.LDT
383022.5170.2355 TYPRO-3830-840-1830-UGR.LDT
405033.8119.8250 TYPRO-4050-840-1830-UGR.LDT
540045.0120.0250 TYPRO-5400-840-1830-UGR.LDT
574033.8169.8355 TYPRO-5740-840-1830-UGR.LDT
765045.0170.0355 TYPRO-7650-840-1830-UGR.LDT
7575 · 750 x 750mm
Output lmWlm/WEmergency lm (2 W)Photometric file
300025.0120.0250 TYPRO-3000-840-7575-UGR.LDT
425025.0170.0355 TYPRO-4250-840-7575-UGR.LDT
450037.5120.0250 TYPRO-4500-840-7575-UGR.LDT
600050.0120.0250 TYPRO-6000-840-7575-UGR.LDT
638037.5170.1355 TYPRO-6380-840-7575-UGR.LDT
850050.0170.0355 TYPRO-8500-840-7575-UGR.LDT

Light distribution

cd/klm
100200300400500
C0–C180 C90–C270

Intensities in cd/klm, so the shape applies to every output.

Part-code builder

Pick one option in each position. Every combination shown is a valid build.

1 Range
TYRO PRO
5 Tile size
600 x 600mm tile (panel 599 x 599)
2 Output (lm)
3,600 lm Depends on: Tile size
3 CRI / CCT
80 CRI, 4000 K
4 Control
DALI dimming
6 Frame colour
White, RAL 9010 (to match SAS)
7 Ceiling system
SAS150 clip-in
8 Diffuser
Micro-prismatic diffuser, UGR<19
9 Emergency
No emergency
Your part code Made to project order: MOQs apply, lead time approximately 12–16 weeks. The output follows the tile size; other outputs (SPEC), bespoke sizes and other ceiling systems to order.
Add to schedule
Free lighting design service Not sure which output? Send us the drawings. We lay out the scheme with TYRO PRO: CLIP-IN (SAS150), calculate it in Relux to EN 12464-1 and return marked-up plans with part codes.
Request a lighting design

Features

  1. 01Made for clip-in metal ceilings: SAS120 / SAS150 and others
  2. 02Flush with the tiles; brackets included, fitted without tools
  3. 0310 standard tile sizes from 300 x 300 to 750 x 750mm
  4. 04Three outputs per size; 120 or 170 lm/W, up to 8,500 lm
  5. 05Micro-prismatic diffuser, UGR<19
  6. 063000 to 6000 K at 80 CRI, or 90 CRI 4000 K; RAL 9010 frame
  7. 07Tridonic fixed output or DALI; Casambi wireless (bDW)
  8. 08Made to project order: MOQs apply, about 12–16 weeks

Specification

IP
IP20
IK
IK04
UGR
<19
Colour options
830, 835, 840, 860, 940
Controls
FI, DALI, swDIM, bDW
Emergency
EM, EMST, EMD2
Mounting
Recessed in clip-in metal ceilings
Finish
WH White (RAL9010)
Supply
230 V 50 Hz
Electrical class
Class II
Dimensions
Tile size less 1mm, from 30mm deep (edge-lit or back-lit to suit the ceiling): 300x300, 300x600, 300x900, 300x1200, 300x1500, 300x1800, 500x500, 600x600, 600x1200, 750x750mm; bespoke sizes to order
Warranty
5 years

Control gear, standards & warranty

  • UKCA
  • CE
  • RoHS
  • WEEE
  • 230 V 50 Hz
  • Class II
  • IP20
  • Emergency BS 5266-1

Tridonic driver as standard. Helvar, Philips, Inventronics and unbranded options available upon request.

diVa five year warranty

Downloads