01

How a part code works.

Each segment is one choice, in a fixed order, and every code means the same thing on every range.

  1. 01 PLLED Range
  2. 02 1250 Output (lm)
  3. 03 840 CRI / CCT
  4. 04 FI Control gear
  5. 05 WH Finish
  6. 06 240 Size (mm)
  7. 07 EM Emergency

Outputs are lumens, not watts. 1250 means 1,250 lm; the matching wattage is on the datasheet.

Colour codes read CRI then CCT. 840 is 80 CRI at 4000 K; 930 is 90 CRI at 3000 K.

Options you don’t need are left out. No emergency, no emergency code.

Build it on the product page. Every updated range has a part-code builder that only offers valid combinations, and shows the matching photometric file. Try it on PLUTO LED.

A few partner ranges (SPY, the BOYA family, ASTRA 90 SUSPENDED and the TUPOLI 70 range) keep their supplier’s part codes; their datasheets set them out.

02

Code dictionary.

Every part code starts with its range code, followed by the option codes used across our ranges. Numbers for output, size and beam angle are set per range and shown on each datasheet.

Range codes · 223 ranges

ADAAR
ADAAR
ADAAR I-LIGHT
ADAAR I-LIGHT
APRB LED
APRB LED
ASTRA 90 SUSP
ASTRA 90 SUSPENDED
ASTRA 90 SUSP UP&DN
ASTRA 90 SUSPENDED UP&DOWN
BOYA TORUS
BOYA TORUS
CARDAN SUSP
CARDAN SUSPENDED
CORINTH EXTREME
CORINTH EXTREME
CORINTH EXTREME SF
CORINTH EXTREME SURFACE
DYNASTES
DYNASTES
EON
EON
EXIT2LEDBOX
EXIT 2 LED BOX
EXIT3LEDBOX
EXIT 3 LED BOX
EXIT4LEDBOX
EXIT 4 LED BOX
EXITEDGE
EXIT EDGE
EXITLED1
EXIT LED 1
EXITLED2
EXIT LED 2
EXITLEDBOXIP65
EXIT LED BOX IP65
EXITWEDGE
EXIT WEDGE
HALO BOYA 40 DN
HALO BOYA 40 DOWN
HALO BOYA 90 DN
HALO BOYA 90 DOWN
HALO BOYA 90 UP&DN
HALO BOYA 90 UP&DOWN
HALO BOYA 150 DN
HALO BOYA 150 DOWN
HALO BOYA 150 UP&DN
HALO BOYA 150 UP&DOWN
HALO BOYA ACOUSTIC
HALO BOYA ACOUSTIC
HALO IRIS 140 OUT
HALO IRIS 140
HEXA BOYA DN
HEXA BOYA
LED3EM
LED3EM
LED8-60/450
LED8-60 STRIP
LED8-120/900
LED8-120 STRIP
LED12-60/RGBTW
LED12-60 RGBTW STRIP
LED12-60/RGBW
LED12-60 RGBW STRIP
LED12-96/RGBW
LED12-96 RGBW STRIP
ONETRACK
ONETRACK
OSGU10
OSSA GU10
OTGU10
OTOS GU10
OTGU10PIR
OTOS GU10 PIR
PIR/EBDSPIR-CB-DD
EBDSPIR-CB-DD CASAMBI PIR
PIR/FDP-301SR-L2-TG
FDP-301SR-L2-TG ZHAGA PIR
POIG3
POI G3
PR/RGBW/CTRL/RF-WP24
RF RGBW Touch Controller (24V)
SIGA I-LIGHT
SIGA I-LIGHT
SIOPILOS
SIOPILOS
SPY 33 ACOUSTIC
SPY 33 ACOUSTIC
SPY 33 SF DN
SPY 33 SURFACE
SPY 33 SUSP DN
SPY 33 SUSPENDED
SPY 33 SUSP UP&DN
SPY 33 SUSPENDED UP&DN
SPY 55 ACOUSTIC
SPY 55 ACOUSTIC
SPY 55 RE DN
SPY 55 RECESSED
SPY 55 SF DN
SPY 55 SURFACE
SPY 55 SUSP DN
SPY 55 SUSPENDED
SPY 55 SUSP UP&DN
SPY 55 SUSPENDED UP&DN
SPY 85 ACOUSTIC
SPY 85 ACOUSTIC
SPY 85 RE DN
SPY 85 RECESSED
SPY 85 SF DN
SPY 85 SURFACE
SPY 85 SUSP DN
SPY 85 SUSPENDED
TRACKEM
TRACK EM
TUPOLI 38
TUPOLI 38
TUPOLI 55
TUPOLI 55
TUPOLI 70
TUPOLI 70
TUPOLI 70 IP65
TUPOLI 70 IP65
TUPOLI 70-360
TUPOLI 70-360
TUPOLI I-LIGHT
TUPOLI I-LIGHT
TYIP65
TYRO IP65
VASILISSA
VASILISSA
ZELITE
ZEUS LITE

Emergency

EM
3hr emergency, manual test
EMST
Self-test emergency
EMD2
DALI-2 emergency
REM
Remote 3hr emergency, manual test
REMST
Remote self-test emergency
REMD2
Remote DALI-2 emergency
M
Maintained · Emergency-only fittings
NM
Non-maintained · Emergency-only fittings
ST
Self-test · Emergency-only fittings

Control gear

FI
Fixed output
DALI
DALI dimming · DALI-2 addressable on emergency-only fittings
MDIM
Mains dimming
CF
Corridor function
CF10
Corridor function, 10% background level · HERCULES LED; other levels programmed to order
1-10V
1-10V dimming
MS
Integral microwave sensor · HERCULES LED twin 1200 and 1500 only
MSD2
DALI-2 microwave sensor · HERCULES LED twin 1200 and 1500; DALI gear only
bDW
Casambi / basicDIM wireless
DT8
DALI DT8 (colour / tunable white control)
TW
Tunable white · CCT range given per product
RGBW
RGBW colour changing
DMX
DMX control · RGBW products
DMXP
DMX pixel control · LED strip products

Colour rendering and temperature

830
80 CRI, 3000 K
835
80 CRI, 3500 K
840
80 CRI, 4000 K
850
80 CRI, 5000 K
860
80 CRI, 6000 K
865
80 CRI, 6500 K
930
90 CRI, 3000 K
940
90 CRI, 4000 K

Finishes

WH
White · RAL given per product
BL
Black · RAL given per product
SL
Silver
RED
Red
CPG
Champagne
CHG
Charcoal grey
AGD
Antique gold
BLM
Black marble
TWH
Translucent white
TBL
Translucent blue
TGR
Translucent green
TRE
Translucent red

Optics, diffusers and accessories

OD
Opal diffuser
UGR
Prismatic diffuser, UGR<19
MAT
Matt reflector
SSP
Semi-specular reflector
SNT
Snoot
ES
Eye snoot
SCG
Sonar cage
GRL
Grille
SMK
Smoke transparent shade

Mounting and installation

PB
Plasterboard fixing (prepared aperture)
SS
Stainless steel clips · HERCULES LED
PBCL
Plasterboard clips only · TYRO
PBFF
Plasterboard full frame · TYRO
PBB
Polycarbonate body · ECHO, ETNA
FLF
Flat fascia · PROTEUS WALL
ALF
Angled fascia · PROTEUS WALL
HB
Hanging blade panel · EXIT LED 3
1mSU
1 metre suspension kit
2mSU
2 metre suspension kit
3mSU
3 metre suspension kit

Exit sign legends

ISOAU
British Standard arrow up
ISOAD
British Standard arrow down
ISOAL
British Standard arrow left
ISOAR
British Standard arrow right
ISOALR
British Standard arrow left / right · Double-sided
ISOAX
British Standard arrow, direction to be advised
ECAX
European arrow legend, direction to be advised
03

Photometrics, ready for Relux.

EULUMDAT (.LDT) files, free to registered specifiers.

  • Named by part code. PLLED-1250-840-240.LDT is the file for that exact build, so the right file goes straight into your calculation.
  • Checked against the datasheet. Luminous flux and wattage in each file match the published figures.
  • Distribution on every product page. The polar curve is drawn in cd/klm from the same file, so its shape holds for every output.
  • Need a file that isn’t listed? Our technical team can supply project-specific photometrics on request.
04

Emergency, built in.

Integral or remote emergency, coded the same way on every range that offers it, to suit BS 5266-1 schemes.

Luminaires

EM 3hr emergency, manual test; EMST self-test; EMD2 DALI-2 emergency. Remote versions: REM, REMST, REMD2.

Emergency-only fittings

M maintained or NM non-maintained, with ST self-test or DALI (DALI-2 addressable).

Exit signs

British Standard arrow legends: ISOAU up, ISOAD down, ISOAL left, ISOAR right, ISOALR double-sided, or ISOAX to be advised. European arrow legend formats available on request: ECAX, direction to be advised.

Our free lighting design service includes escape-route, open-area and exit sign positions to BS 5266-1.

05

Standards we work to.

Lighting calculations are verified in Relux.

EN 12464-1
Light and lighting: lighting of indoor work places. Our lighting designs are calculated to its illuminance, uniformity and glare limits.
BS EN 60598
Luminaires: general requirements and tests.
BS 5266-1
Emergency lighting: code of practice for escape-route, open-area and exit sign lighting.
IEC 62386 / DALI-2
Digital addressable lighting interface, for addressable control and DALI-2 emergency.
UGR
Unified glare rating, quoted on the datasheet where a range is designed to a limit such as UGR<19.
Part L
Building Regulations: conservation of fuel and power.
BREEAM
Building sustainability assessment.
TM65
CIBSE method for the embodied carbon of building services equipment.
diVa five year warranty
06 · Compliance & warranty

Confirmed per product. Guaranteed for five years.

Compliance marks (such as UKCA, RoHS, WEEE and electrical class) are confirmed for each range and shown as tiles on its datasheet. Every luminaire is made in Britain with branded components, with a Tridonic driver as standard; Helvar, Philips, Inventronics and unbranded options are available upon request.